Sri,
Thanks for your response. Do you know when those attributes will be supported? I have opened a ticket with Cambium asking. I do not know about others, but for me, My network uses VLANs and it is an important aspect of my dynamic provisioning.

Gilbert

On 10/20/2014 10:00 AM, Sriram Chaturvedi via Af wrote:

Hi Gilbert,

VLAN configuration through RADIUS is not yet supported on ePMP. Currently, only MIR and user authentication is supported.

Thanks,

Sriram

*From:*Af [mailto:[email protected]] *On Behalf Of *Gilbert T. Gutierrez, Jr. via Af
*Sent:* Monday, October 20, 2014 11:46 AM
*To:* [email protected]
*Subject:* Re: [AFMUG] ePMP Radius

The latest version of the user guide has some of the attributes. I have gotten authentication to work (using my own certs, the ones I use for the ofdm and fsk product lines) was a challenge though. Also, I am able to pass the throughput attributes. The only issue I am having now is VLANs. Now I never tested vlans on the product prior to attempting radius. Maybe I should try utilizing VLANs first in my test setup without authentication and then implement the radius authentication.

Gilbert

On 10/18/2014 5:39 AM, Patrick Wheeland via Af wrote:

    You may be chasing your tail.  Last I knew, several radius
    attributes weren't supported in ePMP.  It's been almost a year ago
    since I looked into it though.  Perhaps more attribute support has
    been added in software releases since then.  I don't recall seeing
    any mention of attributes in the release notes though.

    -Patrick

    On Fri, Oct 17, 2014 at 5:17 PM, Gilbert T. Gutierrez, Jr. via Af
    <[email protected] <mailto:[email protected]>> wrote:

        I am having issues with Radius. I am using the values that the
        user manual specifies in my dictionary file and I can get the
        subscriber to authenticate and set the bandwidth, but I cannot
        get the Vlan settings to work.

        Dictionary values

        ATTRIBUTE Cambium-Canopy-VLIGVID 21 integer #VLAN Ingress VLAN ID
        ATTRIBUTE Cambium-Canopy-VLMGVID 22 integer #VLAN Management
        VLAN ID
        ATTRIBUTE Cambium-Canopy-ULMB 26 integer #Max Burst Uplink Rate
        ATTRIBUTE Cambium-Canopy-DLMB 27 integer #Max Burst Downlink Rate

        In my radius reply for the user, I am setting
        Cambium-Canopy-VLIGVID:=50 and Cambium-Canopy-VLMGVID:=3. I am
        reaching the AP on Vlan 3 but I cannot see the SM in the
        wireless monitor though the AP homepage shows it registered.

        Can anyone point me in the correct direction?

        Gilbert


Reply via email to