Thanks George,

Yah. Had it V2c, and was trying to see what (if any) changes it made to the RRD files. They were the same, so I suspected something was amiss. I think you also need to poll the Mikrotik-specific OIDs (.1.3.6.1.4.1.14988 + ). The stock interface Data Queries built into cacti don't go there (.1.3.6.1.2.1.2.2.1 +).

I will look at the Fix64Bit plugin too.

bp
<part-15@SkylineBroadbandService>

On 11/12/2014 11:01 AM, George Skorup (Cyber Broadcasting) via Af wrote:
If you're set to in/out bits, then you're on 32bit counters. in/out bits (64bit) is what you want. There's completely different OIDs for in/out 64bit octets, called ifInHCOctets or something like that.

You can convert a 32bit graph/RRD to 64 using the Fix64Bit plugin. All the data stays intact. I believe you need to be polling the host as SNMP v2 to get the 64-bit counters as well.

On 11/12/2014 12:02 PM, Bill Prince via Af wrote:

I noticed that we're using 32-bit counters on some of our Mikrotik interfaces, and they are over-running the counter between 5-minute intervals. I added new counters that identify themselves as 64-bit counters when I add them, but for all intents and purposes the RRD files look the same. I tried running rrdtool info on them, but nothing shouts out "64-bit!". Is there a way to confirm that an RRD file is actually 64-bit?