Looks like something goofy with the second sync injector. Data on index
2 looks sort of like the data a sync injector normally shows on the
String I/O tab (like below). Try unplugging the second one, and see if
it feels better.
If it does, you can try setting the serial # to zero then rescan to see
if it will pick it up.
bp
<part-15@SkylineBroadbandService>
On 11/13/2014 4:16 PM, Plexicomm Admin via Af wrote:
So I have two SyncInjectors connected to this SiteMonitor. The second
one will not communicate properly (see screen shot below). I tried
rebooting the base, different jumpers, defaulting, no luck. All three
items are brand new.
Dan English
Plexicomm - Internet Solutions
[email protected] | 1.866.759.4678 x103
Fax: 1.866.852.4688 | Emergency Support: 1.866.759.9713