Sweet!  I have everything fused.

Still having problems keeping these APs powered/linked though.  Thought I'd
ask if they could damage or infect the AP somehow.

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Dec 9, 2014 8:35 PM, "George Skorup (Cyber Broadcasting) via Af" <
[email protected]> wrote:

>  Well, if it's not HV, then it would obviously clamp the PoE voltage. And
> if you're not over-current protecting, then yeah, it'll probably burn up
> the components on the card. I did that on one of the GigE-APC-POE's.
> Powered an airFiber on the bench and some static discharged. No fuse, no
> grounding. It just smoked until I unplugged it. There was a LOT of current
> available (>6A of 56VDC). Stupid me.
>
> But I have had protected over-current situations. Fuse blew and the SS
> still works fine. Nearby lightning strikes inducing some surges.
>
> On 12/9/2014 7:28 PM, Josh Luthman via Af wrote:
>
>  When you say boom you mean the card would appear damaged?  What if you
> put the card in another situation and just do typical ethernet, would it
> work?
>
>  My problem is one AP doesn't turn on at all, two have ethernet problems
> (link up/down), one reboots when I hit refresh (seriously)
>
>  I ordered 12 and from my pictures I can see the middle set says HV in
> black ink.  Unfortunately that means I definitely can't see the ink on the
> outer two cases so I'll have to climb to see if they're HV for sure.
>
>
>  Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
> On Tue, Dec 9, 2014 at 8:20 PM, George Skorup (Cyber Broadcasting) via Af
> <[email protected]> wrote:
>
>> I think all pins or pairs on the non-PoE GigESS's are clamped under 10
>> volts. So.. boom?
>>
>> Are you sure you didn't get regular 10/100 APC PoE SS's? And that's why
>> your GigE isn't working?
>>
>> I believe the GigESS-HV's are pretty clearly marked/stamped as HV. At
>> least the ones I have in the PRM24 chassis in the NOC are. Yep, just
>> looked, the back of the handle is stamped HV.
>>
>>
>> On 12/9/2014 6:49 PM, Josh Luthman via Af wrote:
>>
>>> Has anyone plugged one in to see what would happen?  Does the card just
>>> blow as soon as you power it up?
>>>
>>> As far as I know, every APC card I've gotten in the last several months
>>> have been GigEAPC-HV but I'm curious to know what would happen if maybe I
>>> was shipped the wrong units...
>>>
>>> Josh Luthman
>>> Office: 937-552-2340
>>> Direct: 937-552-2343
>>> 1100 Wayne St
>>> Suite 1337
>>> Troy, OH 45373
>>>
>>
>>
>
>

Reply via email to