PS.. We also swapped in 3 of the new 60 degree AC sector antennas yesterday.. We saw a very nice improvement in off axis interference rejection compared to the previous UBNT sector design. On a tower where we couldn't previously find available channels we now were able to find options due to the reduction in splatter from nearby access points. We are probably going to replace all our UBNT sectors with these units over the next few months based on the results. The only possible downside is the vertical beamwidth of these units is very tight at 4 degrees so in many situations you will need one setup for near customers and another for far customers.
Peter Kranz Founder/CEO - Unwired Ltd www.UnwiredLtd.com <http://www.unwiredltd.com/> Desk: 510-868-1614 x100 Mobile: 510-207-0000 [email protected] <mailto:[email protected]>