That's the cut off voltage. At 20.01 it will power off. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Jan 14, 2015 10:04 AM, "Gabriel.wispa" <[email protected]> wrote:
> Yes. It is close to 20v. Or at least it was when it left the shop. I will > have my tower guy check when he is out there this afternoon. > > ------------------------------ > -----Original Message----- > From: "Josh Luthman" <[email protected]> > To: [email protected] > Date: 01/14/15 09:43 > Subject: Re: [AFMUG] ePMP AP acting strange? > > Is your power source close to 20v? > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > On Jan 14, 2015 8:30 AM, "Gabriel Pike" <[email protected]> wrote: > >> Sync is through packetflux injector. I believe so it is working on FSK >> 900 on the same tower. On radios it shows that it is receiving sync. >> >> >> >> *From:* Af [mailto:[email protected]] *On Behalf Of* Josh Baird >> *Sent:* Wednesday, January 14, 2015 8:19 AM >> *To:* [email protected] >> *Subject:* Re: [AFMUG] ePMP AP acting strange? >> >> >> >> What is your sync source? Are you confident that it is working properly? >> >> >> >> On Wed, Jan 14, 2015 at 8:06 AM, Gabriel Pike <[email protected]> >> wrote: >> >> Have any of you had problems with ePMP AP's randomly rebooting? I have >> other gear on the tower that is working fine the issue is with three ePMP >> 2.4 radios. What I am seeing is that the customer is attached and traffic >> is flowing, (customer is 3 meg), then bam AP's just reboot. I have a >> trouble ticket open with Cambium but I am wondering if anyone else is >> experiencing this? >> >> >> >> Gabriel >> >> >> >> >> >> >> > > >