I wish there was a way to produce a standard for the product which was useful, but because of the dynamic nature of the expansion bus, and some limitations of the snmp stack I use, it's never going to be as static as one would like.
Along with producing standard MIB files to at least define the columns in the tables, I am working on some plugins for different monitoring tools to make this easier. I'll look at that binary tab when I'm back in the office mid next week. I know it used to work. Not sure what changed. Probably a good excuse to add copy oid to the clipboard support for the newer browsers which support this functionality. On Apr 2, 2015 3:31 PM, "Josh Luthman" <[email protected]> wrote: > Hey Forrest. How about a MIB? Don't go all Ubnt on us! > > Different OID for each SiteMonitor =( > > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Thu, Apr 2, 2015 at 5:25 PM, Josh Luthman <[email protected]> > wrote: > >> I think it is 1.3.6.1.4.1.32050.2.1.26.5.45 for me >> >> 1.3.6.1.4.1.32050.2.1.26.5.[0-45+] with 5 being the "value" for this >> one. Confused, but I've got my answer! >> >> Thanks for the help guys. >> >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Thu, Apr 2, 2015 at 5:20 PM, Josh Luthman <[email protected] >> > wrote: >> >>> On the web interface, nothing on the Binary IO page gives me an OID. It >>> does work on Base/Expansion Unit pages. >>> >>> On the Binary IO page I see 1pps, no OID. On the Manager I don't see it >>> go all the way to index 45. >>> >>> Walking 1.3.6.1.4.1.32050.2.1.27 >>> 1.3.6.1.4.1.32050.2.1.27.2.[0-42] are descriptions >>> 1.3.6.1.4.1.32050.2.1.27.3.[0-42] are values >>> >>> No description for 1PPS, but I see sats in view, used pulses, early >>> pulses, etc. >>> >>> >>> Josh Luthman >>> Office: 937-552-2340 >>> Direct: 937-552-2343 >>> 1100 Wayne St >>> Suite 1337 >>> Troy, OH 45373 >>> >>> On Thu, Apr 2, 2015 at 5:17 PM, Forrest Christian (List Account) < >>> [email protected]> wrote: >>> >>>> It's also in the web interface... The hover interface that is. >>>> On Apr 2, 2015 3:14 PM, "Josh Luthman" <[email protected]> >>>> wrote: >>>> >>>>> Oh. I didn't realize that worked for the Monitor II units... >>>>> >>>>> >>>>> Josh Luthman >>>>> Office: 937-552-2340 >>>>> Direct: 937-552-2343 >>>>> 1100 Wayne St >>>>> Suite 1337 >>>>> Troy, OH 45373 >>>>> >>>>> On Thu, Apr 2, 2015 at 5:12 PM, Josh Baird <[email protected]> >>>>> wrote: >>>>> >>>>>> Download the Windows app and hover over the 'sync status' field with >>>>>> your mouse. It should give you the OID. >>>>>> >>>>>> On Thu, Apr 2, 2015 at 5:07 PM, Josh Luthman < >>>>>> [email protected]> wrote: >>>>>> >>>>>>> Does anyone know how to get this OID? Or which OID to look to make >>>>>>> sure the SyncInjector is safely putting out "good sync"? >>>>>>> >>>>>>> Josh Luthman >>>>>>> Office: 937-552-2340 >>>>>>> Direct: 937-552-2343 >>>>>>> 1100 Wayne St >>>>>>> Suite 1337 >>>>>>> Troy, OH 45373 >>>>>>> >>>>>> >>>>>> >>>>> >>> >> >