Yes. That's just SM registrations. Or attempted registrations. Look at
Statistics > SM Registration Failures and see if anything interesting is
in there.
One thing I've been seeing on the 3.6 450 is "something" happening and
SM reg attempts going nuts. The AP reports SM's "out of range" and it
has to be rebooted to fix. That hasn't happened in quite a while, but it
was a daily occurrence back when it didn't get above freezing for almost
three weeks straight.
On 5/7/2015 10:27 AM, Dan Petermann wrote:
I have an issue I�m trying to track down.
Does this look normal?
Transmit Control Count : 38
Receive Control Count : 7