For ptp I want max power and then I'll turn it down later.  I don't
remember the rules when I'm on the tower.

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Jun 3, 2015 11:05 PM, "Mathew Howard" <[email protected]> wrote:

> ohhh... I know I've seen that bug before, but I don't remember exactly
> what caused it... I generally don't try setting the power that high in 5.1.
>
> It used to work right... but that was probably in like 2.3 or so.
>
> On Wed, Jun 3, 2015 at 9:13 PM, Josh Luthman <[email protected]>
> wrote:
>
>> In 5.1 you can enter 21 to 26 but it complains when you try to save.
>>
>> Josh Luthman
>> Office: 937-552-2340
>> Direct: 937-552-2343
>> 1100 Wayne St
>> Suite 1337
>> Troy, OH 45373
>> On Jun 3, 2015 9:55 PM, "Mathew Howard" <[email protected]> wrote:
>>
>>> It'll never let you go above 20dbm in 5.1... or possibly 18, I'm not
>>> actually sure - it tells you the max is 18, but it at least used to let me
>>> set it as high as 20, depending on the antenna.
>>>
>>> On Wed, Jun 3, 2015 at 8:53 PM, Mathew Howard <[email protected]>
>>> wrote:
>>>
>>>>
>>>>
>>>> On Wed, Jun 3, 2015 at 8:19 PM, Josh Luthman <
>>>> [email protected]> wrote:
>>>>
>>>>> In 5.7 maybe, not 5.1
>>>>>
>>>>> Josh Luthman
>>>>> Office: 937-552-2340
>>>>> Direct: 937-552-2343
>>>>> 1100 Wayne St
>>>>> Suite 1337
>>>>> Troy, OH 45373
>>>>> On Jun 3, 2015 4:18 PM, "joseph marsh" <[email protected]> wrote:
>>>>>
>>>>>> We don't have a issue with ours yet we just got our stuff in a few
>>>>>> days ago I believe mine is 26dBm
>>>>>> On Jun 3, 2015 2:42 PM, "Josh Luthman" <[email protected]>
>>>>>> wrote:
>>>>>>
>>>>>>> I'm tired of repeating myself.  Maybe no one else cares, but let me
>>>>>>> speak here first.
>>>>>>>
>>>>>>> I'm putting up a 5 GHz AP.  It let's me select 26dBm tx power
>>>>>>> without warning until I hit save.  Then it will give me a red info 
>>>>>>> button
>>>>>>> at the top saying that's too much power.
>>>>>>>
>>>>>>> Well if you knew that value is invalid, why don't you tell me in
>>>>>>> that box like 27+ will???
>>>>>>>
>>>>>>> I know this existed in 2.3.4 but it continues in 2.4.2.  Am I the
>>>>>>> only one that this bothers?  Why not just default it to max power like
>>>>>>> everyone will for isntallation and let ATPC/me turn down the power?
>>>>>>>
>>>>>>> Josh Luthman
>>>>>>> Office: 937-552-2340
>>>>>>> Direct: 937-552-2343
>>>>>>> 1100 Wayne St
>>>>>>> Suite 1337
>>>>>>> Troy, OH 45373
>>>>>>>
>>>>>>
>>>>
>>>
>

Reply via email to