Or maybe it's Chuck doing a test?

bp
<part15sbs{at}gmail{dot}com>

On 12/11/2015 11:49 AM, George Skorup wrote:
Does a reboot of one end or both fix it? Really looks like interference at your Side 1. Link lock = 0 and high MSE while your RSSI is normal.

On 12/11/2015 12:34 PM, [email protected] wrote:
Twice a year for a few weeks we have a Trango Apex 11GHz link that acts up. Here is what we are seeing:

Side 1:
# linktest
        LOCK       RSSI          MSE            BER TX              RX
  1>     0      -43.40 dBm      -7.70 dB  0.00E+00 QPSK            QPSK

Side 2:
# linktest
        LOCK       RSSI          MSE            BER TX              RX
  1>     1      -45.00 dBm      -34.30 dB 0.00E+00 QPSK            64QAM

Any idea what could be causing this? We saw something similar on Giga 11GHz links as well.