Know what never leaks? Bbdge
On Jan 27, 2016 8:20 PM, "George Skorup" <[email protected]> wrote:

> Yeah. If I wasn't clear before, I'm talking about the Primus
> double-jacketed stuff that's a regular unshielded cat5e wrapped in foil and
> another jacket over that. Total garbage. Erich is correct, not even a year
> and it leaks. We re-cabled an entire tower (about 14 runs) and ALL of them
> leaked. We used good TnB Ty-raps. And I'm sure Erich used his standard
> extra wide tape method. So it wasn't the ties being too tight.
>
> Just my opinion. Use it if you want.
>
> On 1/27/2016 7:18 PM, Erich Kaiser wrote:
>
> That Primus double jacket is crap(Leaks within first year of use), use
> single jacket, have not had an issue with it yet.  Use this
> C5CMXT-2152BKWS
>
>
> Erich Kaiser
> North Central Tower
> [email protected]
> Office: 630-621-4804
> Cell: 630-777-9291
>
>
> On Wed, Jan 27, 2016 at 5:03 PM, George Skorup <[email protected]> wrote:
>
>> All of that shit we used ended up leaking. Never again.
>>
>> On 1/27/2016 4:47 PM, Ken Hohhof wrote:
>>
>>> We use the 414 for customer installs but do not like the 416, foil seems
>>> thin and don't like the double jacket.
>>>
>>> -----Original Message----- From: Dennis Burgess
>>> Sent: Wednesday, January 27, 2016 4:34 PM
>>> To: [email protected]
>>> Subject: Re: [AFMUG] Tower Cabling
>>>
>>> We only use
>>> http://www.linktechs.net/productcart/pc/viewPrd.asp?idproduct=191&idcategory=0
>>> anymore.  Towers, clients, and even in office :)
>>>
>>> Dennis Burgess, CTO, Link Technologies, Inc.
>>> [email protected] – 314-735-0270 x103 – www.linktechs.net
>>>
>>> -----Original Message-----
>>> From: Af [mailto:[email protected]] On Behalf Of Gilbert T.
>>> Gutierrez, Jr.
>>> Sent: Wednesday, January 27, 2016 12:22 PM
>>> To: [email protected]
>>> Subject: [AFMUG] Tower Cabling
>>>
>>> What cable do most use for tower installations?
>>>
>>> I am about to install at some new tower sites and wanted to see if
>>> anyone has had extended success with anything. The current cable I use is
>>> Superior Essex BBDGe which is a flooded cable with a corrugated copper
>>> shield. This cable is very thick and bulky and works well on AM tower when
>>> I install on those.
>>>
>>> I saw that Ubiquiti has something that they call TC-CARRIER that looks
>>> like it could meet my needs though I do not know how stable the sheathing
>>> is in the sunlight. I was looking at moving to Cat 6 though I have never
>>> come across Cat 6 tower cable.
>>>
>>> Thoughts?
>>>
>>> Gilbert T. Gutierrez, Jr.
>>> Phoenix Internet
>>>
>>>
>>
>
>

Reply via email to