Hi Matt,

Yes, the config import failure is due to the auth key. This bug has has been 
addressed in 14.1.2 which is currently available as a beta release.

Regarding the 3.65 frequency setting on the SM, add an extra 0 to the 
frequency. So instead of:
snmpset -v 2c -c Canopy 169.254.1.1 .1.3.6.1.4.1.161.19.3.3.2.53.0 s
366000,369000

Use:
snmpset -v 2c -c Canopy 169.254.1.1 .1.3.6.1.4.1.161.19.3.3.2.53.0 s
3660000,3690000

This is because the raster is now 1 kHz while it was previously 50 kHz.

We will update the OID description in 14.1.2 to reflect this change as the 
example in the description is incorrect.

Thanks,
Sriram

Join the Conversation
Cambium Networks Community Forum




On Feb 9, 2016, at 11:56 AM, Matt 
<[email protected]<mailto:[email protected]>> wrote:

worked.  I configure one SM and it works.  Restore the exact same
config to another SM and it won't register too tower.  Restore factory
defaults on it and configure step through web interface and it works
fine again.

On this part I did figure out that the Canopy configuration backup
does not restore the pre-shared authentication key.  Have to enter it
manually each time after applying the configuration file.