Hi Matt, Yes, the config import failure is due to the auth key. This bug has has been addressed in 14.1.2 which is currently available as a beta release.
Regarding the 3.65 frequency setting on the SM, add an extra 0 to the frequency. So instead of: snmpset -v 2c -c Canopy 169.254.1.1 .1.3.6.1.4.1.161.19.3.3.2.53.0 s 366000,369000 Use: snmpset -v 2c -c Canopy 169.254.1.1 .1.3.6.1.4.1.161.19.3.3.2.53.0 s 3660000,3690000 This is because the raster is now 1 kHz while it was previously 50 kHz. We will update the OID description in 14.1.2 to reflect this change as the example in the description is incorrect. Thanks, Sriram Join the Conversation Cambium Networks Community Forum On Feb 9, 2016, at 11:56 AM, Matt <[email protected]<mailto:[email protected]>> wrote: worked. I configure one SM and it works. Restore the exact same config to another SM and it won't register too tower. Restore factory defaults on it and configure step through web interface and it works fine again. On this part I did figure out that the Canopy configuration backup does not restore the pre-shared authentication key. Have to enter it manually each time after applying the configuration file.