George, Call Lee Legler from Yorkville, he is an expert at this stuff. He has installed several Generacs for me and repaired an old dog as well. He will know right away what needs to be done. I would recoemmend him to anyone in the area, the other guy I had out of Newark/Norway area was useless...
Phone:(630) 546-8476 He will also give you a good deal on the generator. Erich Kaiser North Central Tower [email protected] Office: 630-621-4804 Cell: 630-777-9291 On Thu, Apr 7, 2016 at 8:12 PM, George Skorup <[email protected]> wrote: > Which Generac doesn't offer on these. I don't want to piss away a 5yr > warranty from the get-go. > > On 4/7/2016 6:48 PM, Chuck McCown wrote: > >> Yes, if you want to permanently change it over, but there are dual >> regulators and the air mixing device. >> >> -----Original Message----- From: George Skorup >> Sent: Thursday, April 07, 2016 5:11 PM >> To: [email protected] >> Subject: Re: [AFMUG] LP and NG on genset? >> >> OK, so apparently the regulator jet has to be swapped when changing fuel >> types. As well as access to the dealer password locked section in the >> controller to select NG or LP. Dumb. Oh well, we'll just order the LP >> jet and keep it in a safe place. >> >> On 4/7/2016 3:07 PM, Josh Reynolds wrote: >> >>> 48Kw, Ford v8 on NG >>> >>> Generac RTSW200A3 >>> >>> On Thu, Apr 7, 2016 at 2:49 PM, George Skorup <[email protected]> wrote: >>> >>>> Nice. What size and which transfer switch did you use? >>>> >>>> On 4/7/2016 2:43 PM, Josh Reynolds wrote: >>>> >>>>> Here's our new baby. >>>>> https://www.dropbox.com/sc/ctcqnbl1cun088e/AAA19j1kF8M9gaCPX_6CVMr4a >>>>> >>>>> On Thu, Apr 7, 2016 at 2:29 PM, George Skorup <[email protected]> >>>>> wrote: >>>>> >>>>>> We're most likely going to get the 22kw. I believe Generac has these >>>>>> newer >>>>>> units set up so that all you need is to select the correct regulator >>>>>> for >>>>>> the >>>>>> desired fuel type. So it'd be ideal if we could just plumb two >>>>>> regulators >>>>>> and some valves. Guess we'll talk to the dealer and see if we can >>>>>> make it >>>>>> work. >>>>>> >>>>>> >>>>>> On 4/7/2016 1:20 PM, Chuck McCown wrote: >>>>>> >>>>>>> Two ways. Almost certain Generac has a dual fuel carb that will LP >>>>>>> and >>>>>>> NG. >>>>>>> >>>>>>> But you can always convert LP to work with an unaltered NG device >>>>>>> with >>>>>>> an >>>>>>> air mixer. >>>>>>> >>>>>>> Lots of mission critical NG installations have a large LP tank too >>>>>>> with >>>>>>> this air mixer device. The NG companies call them a carburetor. I >>>>>>> think it >>>>>>> just mixes a fixed amount of air with the LP and sends it down the >>>>>>> line >>>>>>> at >>>>>>> the right pressure. >>>>>>> >>>>>>> -----Original Message----- From: George Skorup >>>>>>> Sent: Thursday, April 07, 2016 12:04 PM >>>>>>> To: [email protected] >>>>>>> Subject: [AFMUG] LP and NG on genset? >>>>>>> >>>>>>> We're going to be putting in one of the Generac 1800RPM quiet models >>>>>>> at >>>>>>> our office (so the neighbors won't bitch too much about the noise of >>>>>>> a >>>>>>> 3600). So here's one of the potential problems we're worried about, >>>>>>> because it happened. They shut off the natural gas after the tornado >>>>>>> last year because houses were blown away and gas was leaking >>>>>>> everywhere. >>>>>>> If that were to happen again, then our shiny expensive new generator >>>>>>> will be sitting there doing nothing. So we're thinking about doing a >>>>>>> LP >>>>>>> tank as backup, but would like to have the primary be NG. Has anyone >>>>>>> done this? Two regulators and valves perhaps? I don't have a problem >>>>>>> manually turning some valves, but I don't wanna be out there at >>>>>>> o'dark:30 in the rain doing plumbing. >>>>>>> >>>>>> >>>>>> >> >