No,  Cambium elected  to drop the traditional sync over power on the 450M.

So,  you either need to use timing port sync (via the aux port) or use what
they're calling cambium sync.

The 1U injector is very close.  I need to finish validation on the latest
board revisions and then will be releasing it to production assuming there
isn't some showstopper I missed.

On Nov 14, 2016 7:34 PM, "Matt" <[email protected]> wrote:

> Shouldn't the sync over power for the 450M be the same as PMP450i?
>
> How is the 1u sync injector coming?
>
>
> On Mon, Nov 14, 2016 at 12:30 PM, Forrest Christian (List Account)
> <[email protected]> wrote:
> > All of the currently shipping syncbox product line are compatible.  For
> sync
> > over power, I have the specs, but the design isn't done yet.
> >
> >
> > On Nov 14, 2016 5:40 PM, "Sam Lambie" <[email protected]> wrote:
> >>
> >> A question for Forrest mostly. Have you come up with a timing product
> for
> >> the 450m AP yet? If not, have you got a timeline for release?
> >>
> >> Sam
> >>
> >> --
> >> --
> >> Sam Lambie
> >> Taosnet Wireless Tech.
> >> 575-758-7598 Office
> >> www.Taosnet.com
>

Reply via email to