O with the line through it is a geometric dimensioning and tolerancing symbol. Means Diameter.
I need to take another look at that drawing. The pipe actually hangs off the ends by a couple of inches on each end now and that diameter should be 1.66” (but that is before galvanizing). From: Josh Luthman Sent: Monday, January 16, 2017 10:21 AM To: [email protected] Subject: [AFMUG] MTOWP pipe 1.685 inside or outside? http://www.mccowntech.com/product_images/import/M-TOW-P.PDF I'm not familiar with the O and a line through it here. I'm assume that's outside diameter, is that right? Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373