We bought a gazillion of these things last year for a project with 10"
diameter poles:
http://www.commscope.com/catalog/wireless/product_details.aspx?id=2234
It says there the small side is 4-9", but it's waaay smaller than that.
Like 2-4" maybe.
I see 6" round legs all the time. Bigger than that I've only seen maybe
once or twice on a tower leg. This pole thing was kind of a unique
project.
------ Original Message ------
From: "George Skorup" <[email protected]>
To: [email protected]
Sent: 1/16/2017 8:02:11 PM
Subject: Re: [AFMUG] Pipe mounts
That was me. The angle-iron leg deal I was talking about, I don't
actually need anything specifically designed for angle-iron, we simply
turn the back clamp inwards. Works perfectly fine. However, like I
said, the back side of the angle is about 5-3/4" if I remember. That's
the tower where we order clamp halves that are 7" hole to hole center.
A couple other examples that I can give... Angle iron leg, 6-3/4",
sloped. Round leg, 8-1/4", sloped. Angle leg, 12-3/4", sloped. (old
AT&T Long-Lines sites, big mothertruckers from ground to 125 feet)
We're on so much different shit, we pretty much have to order what we
need for the particular site we'll be working at. And most of the time
on free-standers, the legs get smaller as you go up. So we might need
to put dishes at 100-140 feet and sectors at 240-260, which means two
completely different sets of mounts for one site.
I would say a model that can accommodate up to 4.5" OD and another for
4.5 to 9" OD, sloped or not. For your 1-to-2 pipe arrangement, most
towers will fall in one of those two. For the big leg sites, I'm not as
worried since, as I mentioned, that's mostly for mounting dishes lower.
We ordered I don't even know how many of these kits last year. 3' HP
dishes on 4.5" pipes adapted to 6" to 8" legs. Some angle, some round.
Some sloped, some not.
http://www.ciwireless.com/product/welded-pipe-to-pipe-adaptor-set-for-tapered-round-members-2-38-in-5-in-od-pipe-to-4-in-9-in-od-pipe/
On 1/16/2017 2:38 PM, Chuck McCown wrote:
I have been asked to spin versions of my tower mounts that work on
angle iron legs. OK, done. Will be released soon for general
availability.
Now I am getting request for larger units that will fit a 5” pipe. We
currently will fit a 4.5” pipe.
If I spin a larger version, shall I go 6” or??? Someone recently
suggested 7” center to center on the bolts which would fit over a 6.5”
pipe.
Are there some standard tower leg and mounting pipe increments I need
to look at?