I was gonna say water in the case myself... On Tue, May 23, 2017 at 3:42 PM, Eric Muehleisen <[email protected]> wrote:
> I had something very similar to this recently. There ended up being a lot > of water in the case. It worked for a short while after drying but > eventually died on the bench. > > On Tue, May 23, 2017 at 1:03 PM, Peter Kranz <[email protected]> > wrote: > >> I have a PMP450 AP that seems ‘deadish’.. any thoughts? >> >> >> >> I cannot ping it, telnet into it, HTTP into it >> >> But the yellow traffic indicator light on the unit blinks >> >> It sends out a LLDP_Multicast message every 60 seconds or so with the >> name on the unit on it >> >> I’ve tried the default cable and power cycle procedures >> >> >> >> >> >> >> *Peter Kranz*www.UnwiredLtd.com <http://www.unwiredltd.com/> >> Desk: 510-868-1614 x100 <(510)%20868-1614> >> Mobile: 510-207-0000 <(510)%20207-0000> >> [email protected] >> >> >> > >