How long is your cable run? Been seeing similar issues with SAF to Mikrotik CRS. Removed some excess cable off one tower and helped. Still have some errors though. We have APC-GIGE arrestors in the loop too. I also have issues getting gigabit with PTP450, SyncInjector too CRS when using APC-GIGE arrestors. I guess that's an issue with Canopy sync over power? If we take the arrestor out they seem to hold fine. I imagine its a matter of adding all the parts together that drags it down.
On Thu, Jul 13, 2017 at 6:00 PM, Steve Jones <[email protected]> wrote: > is there any known issue with these things talking to each other. the two > luminas on a link drop to 100mb on the ethernet, I have a script somebody > gave me here to flap the mikrotik port and bring it back up to full gig. > They both have the transtector SS that came with them. I locked the mikrotik > to 1000 but it still flaps like the SAF occasionally tries to renegotiate > like the donald. Saf only shows 100 as an option to lock it
