We have seen a number of them.  Usually where the gortex vent cloth wasn’t 
centered in the hole, or the retaining ring wasn’t fully staked in.   I usually 
plug the vent with mastic and leave out the plug in the timing port grommet.

Mark


> On Sep 21, 2017, at 8:40 PM, Roland Houin <rho...@fourway.net> wrote:
> 
> yes, we've had a few..
> 
> roland
> 
> 
>> I'm investigating a PMP450 5ghz AP (old unit - the original ones that came
> with the FSK port) that failed on the tower. RJ45 and especially RJ12 ports
> have white dots on the pins. Looking in the case, there seems to be evidence 
> of
> water intrusion coming from the little temperature/humidity control
> membrane-covered hole in back. But a quick test of dripping water on the case
> does not cause water intrusion in that hole. Has anyone else seen such issues
> with older PMP450 APs? <
> 

Reply via email to