To comment on the following update, log in, then open the issue: http://www.openoffice.org/issues/show_bug.cgi?id=110288 Issue #|110288 Summary|new CONVERT_ADD factors for "uk_qt" and "uk_gal" are i |ncorrect Component|Spreadsheet Version|OOo 3.2 Platform|PC URL|http://user.services.openoffice.org/en/forum/viewtopic |.php?f=9&t=28814 OS/Version|All Status|UNCONFIRMED Status whiteboard| Keywords| Resolution| Issue type|DEFECT Priority|P3 Subcomponent|programming Assigned to|spreadsheet Reported by|jes
------- Additional comments from [email protected] Sun Mar 21 02:47:52 +0000 2010 ------- >From i99140_patch2.diff attached to Issue 99140: ... + NEWD( "uk_gal", 2.6411458333333333E-01, CDC_Volume ); // U.K. / Imperial gallon ?? + NEWD( "uk_qt", 1.0564583333333333E00, CDC_Volume ); // U.K. / Imperial quart ?? Those factors are the same as US Gallon/Quart, so CONVERT_ADD currently recognizes imperial units but gives incorrect results for those conversions. The correct factors are simply 1/8 and 1/4 of the "uk_pint" factor, which is correct. Using those integer factors, the lines in scaddins/source/analysis/analysishelper.cxx should look something like this: NEWD( "uk_gal", 2.199694619402070E-01, CDC_Volume ); // U.K. / Imperial gallon NEWD( "uk_qt", 8.798778477608300E-01, CDC_Volume ); // U.K. / Imperial quart Spreadsheet attached for testing. --------------------------------------------------------------------- Please do not reply to this automatically generated notification from Issue Tracker. Please log onto the website and enter your comments. http://qa.openoffice.org/issue_handling/project_issues.html#notification --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected] --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]