Hi Paul,

Thanks for the clarification. I was trying to implement the LSF as a Service 
App and when I tried to implement the org.allseen.LSF.LampDetails interface  
the app crashes on launch, but when I reduced the the number of properties in 
the interface to <10 the app functions without any problems.

Any comments on the same?


Thanks and regards

Ajit

________________________________
From: Paul Sigurdson <[email protected]>
Sent: Friday, March 11, 2016 4:02 PM
To: Sajjan Raj, Ajit
Cc: [email protected]
Subject: Re: [Allseen-core] Limit on number of Properties in the BusObject

Not as such. Definitely not 10. There are Alljoyn interfaces defined in Android 
apps with > 10 properties.

-Paul

On Mar 10, 2016, at 8:58 AM, Sajjan Raj, Ajit 
<[email protected]<mailto:[email protected]>>
 wrote:

Is there a Limit on the number of properties that a BusObject can hold ?
I was writing a Code for Android and my Interface has more than 10 different 
properties. But as soon as the app is launched , it crashes.
When i reduce the number of properties to 10,  the app runs perfectly fine.

Thanks
Ajit


_______________________________________________
Allseen-core mailing list
[email protected]<mailto:[email protected]>
https://lists.allseenalliance.org/mailman/listinfo/allseen-core

_______________________________________________
Allseen-core mailing list
[email protected]
https://lists.allseenalliance.org/mailman/listinfo/allseen-core