In message <[EMAIL PROTECTED]>you write:
>dave willis wrote:
>> 
>> On Thu, 29 Nov 2001, Abramo Bagnara wrote:
>> 
>> > Q: with the ice1712 it is possible to run two or more cards in sync
>> > A: Yes, if you're not thinking to share the same clock chip (i.e. some
>> > drift is possible).
>> 
>> why can't i share the same clock chip?  i thought i read somewhere that i
>> could link up to 4 of these cards.
>
>AFAIK only Delta 1010 permit that.

doesn't Delta 1010 have word clock i/o ? you can sync them like that.

the hammerfall series also allows for an internal clock connection
cable.