>Your patch doesn't take care about frequencies other than 48000Hz, because >stimer is absolute 48000Hz timer, so the spurious threshold should be >adjusted for other sample rates as well. I've put your code with my >modifications to the CVS tree.
my attempt was to make it independent of srate by saying "if the delta is less than half the smallest possible period size, then its bogus". --p _______________________________________________ Alsa-devel mailing list [EMAIL PROTECTED] https://lists.sourceforge.net/lists/listinfo/alsa-devel