I think snd-serialmidi is broken for MS-124W MIDI interfaces in MB mode,
and that it has something to do with running status not being handled
correctly.

You need my patch, which I posted previously, to get MB mode working at
all.

The MS-124W seems to work in SA mode.

When I run this interface over a USB serial converter, there seems to be
60 ms round trip time for a MIDI byte. Sad news indeed.

-- 