Clemens

Many thanks for the input, however I cannot seem to get the linear to work 
after a multi, even if after a multi -> rate -> linear -> slave.

Anything that I do that specifies a format after the multi seems to fail.

Is there another way you could recommend maybe instead of using the multi for 
sample copying?

Regards

Ed Stark


> On 7 Dec 2016, at 12:03, Clemens Ladisch <cladi...@googlemail.com> wrote:
> 
> Ed Stark wrote:
>> To combine the analogue and the digital I am using a multi, but cannot
>> specify different formats for the slaves when using a multi. Ideally
>> I want to set the analogue at 32bit and force the digital to 24bit
> 
> A single PCM device uses a single format.  The multi plugin just copies
> samples, so its slave devices must use the same format.
> 
> However, you can use the linear plugin to automatically convert the
> sample format between itself and its slave.
> 
> 
> Regards,
> Clemens


------------------------------------------------------------------------------