Hi folks,

I've been looking over the Telemetrum schematic and trying to figure out
whether the header power switch (v_lipo/v_charge) meets the NAR Level 3
requirement to "physically break the connection between a pyrotechnic system
and its power source" to safe the charges externally.  My limited EE
background says there's no way the output transistors are going to pass
current without the switch turned on, but I don't know how the NAR feels
about this.  Any thoughts?

I was hoping I could get away with just the one switch for the Telemetrum,
plus whatever switch(es) my (heterogeneous) backup needs.  Otherwise, I can
see my avionics bay quickly turning into a bit of a rat's nest.

Thanks,
Casey Barker