Stewart Campbell <[email protected]> writes:

> You haven't got an older Teledongle have you?  Some of the 
> earlier ones had problems with the RF chip.

It wasn't all earlier units, fwiw, but specific date codes on the CC1111
RF system on chip parts from just after TI moved production from one fab
to another.  The units built with suspect parts are

   TeleBT v1.1 sn 1070-1189
   TeleDongle v0.2b sn 1378-1593

Some of these work just fine, but we had ridiculously high failure
rates in production testing, and a few more have given customers trouble.

If you have a unit in one of these ranges that's giving you RF trouble,
don't waste *any* time trying to re-cal it or anything like that, just
let me know so I can set up an RMA number for you and replace it.

Bdale

Attachment: signature.asc
Description: PGP signature

_______________________________________________
altusmetrum mailing list
[email protected]
http://lists.gag.com/mailman/listinfo/altusmetrum

Reply via email to