--On Friday, April 12, 2002 11:21:23 -0700 Joshua Hamor <[EMAIL PROTECTED]> wrote:

> This is what i get everyday from my cron job of amcheck. Any ideas?
>
>> Amanda Tape Server Host Check
>> -----------------------------
>> Holding disk /dumps/amanda: 14044688 KB disk space available, that's plenty
>> amcheck-server: slot 2: date 20020318 label C5102 (active tape)
>> amcheck-server: slot <error>: no tape online
>> amcheck-server: fatal slot mt:: /dev/nrst0: Input/output error
>> ERROR: label C5103 or new tape not found in rack
>>       (expecting tape C5103 or a new tape)

It looks like it checked the label on the tape in the drive, saw that
it was the previous day's, tried to get the changer to get the right
tape and then was unable to read the label for some reason (no tape,
wrong tape, drive not ready, etc.) that the changer script couldn't
handle.
   If you rerun amcheck again without touching anything and it is happy,
I suspect that the changer script needs to wait longer after the tape
change before trying to read the label to give the changer time to
insert the next tape and for the drive to rewind.
   Otherwise try watching the library while you run amcheck and see
what it is trying to do, and how far along it gets before it returns
the error.

Good luck,
Frank


--
Frank Smith                                                [EMAIL PROTECTED]
Systems Administrator                                     Voice: 512-374-4673
Hoover's Online                                             Fax: 512-374-4501