Thanks to Jon, Gene, Chris, Joshua, Jay and Liam for responding last week. I did 
get 
the changer set up, turns out I just had to uncomment two lines in sgen.conf and 
reboot. 
Well it would have been if the changer's default SCSI id was not the same as the 
CD 
drive in solaris but once I got that sorted out mtx worked like a dream.

There is still a couple of questions I have about the changer scripts. Firstly 
what is the 
difference between ch-mtx, ch-zd-mtx and chg-scsi.
I tied getting ch-zd-mtx to work but could not so I used the script that come 
within the mtx distribution which seems to be working.

As most people on the list seem to be using ch-zd-mtx I would rather use that to 
make any future problem solving easier. I set my changerfile with the following 
values (If it's not listed here it has the default):

firstslot=1 
lastslot=10
autoclean=0
offline_before_unload=0
max_drive_wait=300

The chg-zd-mtx script it says to run "/path/to/amanda/libexec/chg-zd-mtx -info". 
When I run this I get different results depending on the values set in the 
changerfile but no matter what setting I put in the changer file the result does 
not make sense.

With cleanslot left at default which is -1 Iget the following error from 
"/path/to/amanda/libexec/chg-zd-mtx -info":

<none> cleanslot ('-1') not numeric in /opt/amanda/etc/amanda/CHANGER.conf

If I change cleanslot to 10 I get:

<none> cleancycle ('120') not numeric in /opt/amanda/etc/amanda/CHANGER.conf

I don't understand any of these especially since the script does not have a 
variable called cleancycle.

I'm running Solaris 8 with amanda 2.4.3 (See I am learning Jon)