I had something very similar to this happen with my AIT-2 changer when it had to be reset to company defaults. Unbeknownst to me, the default tape for the changer (drive? I don't remember) was DLT -- and, when it didn't find AIT-2 tapes, it complained bitterly, but not with any error that was obvious. If you've done anything "interesting" to your changer/drive lately, you just might want to make sure it's still configured correctly.
$.02, Ken D'Ambrosio Sr. SysAdmin, Xanoptix, Inc. > Roberto Samarone Ara�jo (RSA) wrote: > >>Hi, >> >> I have an Amanda Backup that was working fine now, when I try to >> use: >>su -c "/usr/sbin/amlabel Daily1 DAILY1-01" backup, the system return me: >> >> st0: Error with sense data: Current st09:00: sense key Medium >>Error >> Additional sense indicates Write error >> .... >> >> If I try: mt erase /dev/st0, it return me: >> >> st0: Error with sense data: Current st09:00: sense key Medium >>Error >> Additional sense indicates Write error >> mt: /dev/tape: Input/Output error >> >> I change my SDT-9000 tape to a new one and the problem persist. >> >> I saw on the logs the messages: >> >> st0: Block limits 1 - 16777215 bytes >> st0: Error with sense data: Current st09:00 sense key Medium >>Error >> Additional sense indicates Write error >> >> Does anyone could help me please ? When a try to recover a backup >> it >>worked fine. >> >> Roberto Samarone Araujo >> >> >> >> >> > I'd check my perms on /dev/st0 as well...make sure the restore didn't > change any setting back that you may have edited. Otherwise you could > have a hardware problem...but I'd lean more to perms. > > =G=