On Thu, Nov 08, 2007 at 04:26:38PM +0100, Cyrille Bollu wrote: > Hi, > > your e-mail woke me up :-) > > I've tested Amanda a little today and it already works quite good. > ... > My changerfile basically contains: > > firstslot=1 #### First storage slot (element) -- required > lastslot=5 #### Last storage slot (element) -- required > (ndlr: not full yet. I'm still in testing) > cleanslot=23 #### Slot with cleaner tape -- default is "-1" > # #### Set negative to indicate no cleaner > available > driveslot=0 #### Drive slot number. Defaults to 0 > > Basically the tests explained in the chg-zd-mtx script ran successfully > except that for some reason Amanda did not seem to have taken the lastslot > variable into account; When I typed "./chg-zd-mtx -slot next" at slot 5 it > loaded the cleaning cartidge instead of going back to slot 1 (And it tried > to rewind it which it seems it doesn't like). I still have to figure that > out. Then try "amtape". Then I will be able to start to backup the "real > things" (600GB-700GB a day). >
Cleaning tapes, I think, are designed to be one pass only. Each cleaning pass uses a portion of the tape and when the end is reached the tape is discarded. In my limited experience I've found it best to consider cleaning a non- Amanda operation. I.e. I tell chg-zd-mtx there is no cleaning tape AND I leave the cleaning tape out of the changer. When a cleaning operation is necessary I use mt, mtx, and the cleaning tape to manually do the job. jl -- Jon H. LaBadie [EMAIL PROTECTED] JG Computing 4455 Province Line Road (609) 252-0159 Princeton, NJ 08540-4322 (609) 683-7220 (fax)