Jose,

When amanda did the backup, it computed a crc of 6828c030.
But it compute b8d66d3d when it read it from holding disk to flush it.
Do you see that error in the report for all flush attempt?

The holding disk file is not erase because of the crc mismatch.
You can manually remove it (amadmin holding list, amadmin holding 
delete) from the holding disk and force a full backup of that dle.

That's why a added the crc, these kind of errors where undetected before.

Jean-Louis

On 01/11/17 10:24 AM, Jose M Calhariz wrote:
> Hi
>
> I am using amanda 3.5 on my personal server and started to investigate
> a strange problem on my amanda installation.
>
> Since around 10 days ago when it runs the amdump during the nigth, it
> flush the holdingdisk, by starting allways with the same big DLE.
> This means after the DLE is on vTape is not deleted from the
> holdingdisk and will be flushed on the next night.
>
> I found an interesting error message in amdump.20171101031517, I think
> this error is related to the problematic DLE.  And I noticed that the
> file on vTape is broken too, it generates an error from gzip.
>
> driver: result time 549.166 from taper0: PARTIAL worker0-0 00-00001 
> INPUT-ERROR TAPE-GOOD "6828c030:54131462843" "[sec 548.000000 bytes 
> 54131462843 kps 96464.883212 orig-kb 53706460]" "source server crc 
> (6828c030:54131462843) and input server crc (b8d66d3d:54131462843) differ)" ""
>
> This problem possibly was caused by an error on SATA that caused the
> system disk to became read-only.
>
> What logs should I investigate?  Because this is a personal
> installation with private data, I will send the logs to the interested
> persons, not to the list.
>
>
> Kind regards
> Jose M Calhariz
>
This message is the property of CARBONITE, INC. and may contain confidential or 
privileged information.
If this message has been delivered to you by mistake, then do not copy or 
deliver this message to anyone.  Instead, destroy it and notify me by reply 
e-mail