Luc,
The assignment of 'Data Transfer Element 0' to '/dev/nst1' and 'Data
Transfer Element 1' to '/dev/nst0' is done by the kernel.
You can use the 'amtape CONF verify' command to check if you correctly
configured amanda.
Jean-Louis
On 13/01/18 06:40 PM, Luc Lalonde wrote:
Hello Folks,
I’m getting a strange result when I do an ‘amcheck’:
slot 3: Tape device /dev/nst1 is not ready or is empty
slot 4:Slot 4, label '000279L7', mismatch barcode between changer '000280L7'
and tapelist file '000279L7'
ERROR: Slot 4, label '000279L7', mismatch barcode between changer '000280L7'
and tapelist file ‘000279L7'
Here’s what I have in my config file:
define changer spectra-robot {
tapedev "chg-robot:/dev/changer"
property "tape-device” "0=tape:/dev/nst0"
property append "tape-device” "1=tape:/dev/nst1"
device-property "BLOCK_SIZE" "512k"
property "use-slots" "1-47”
}
To get rid of the problem, I reverse the tape device order:
define changer spectra-robot {
tapedev "chg-robot:/dev/changer"
property "tape-device" "1=tape:/dev/nst0"
property append "tape-device" "0=tape:/dev/nst1"
device-property "BLOCK_SIZE" "512k"
property "use-slots" "1-47”
}
Here’s the pertinent lines of the ‘amcheck’ after having made this change:
slot 3: volume '000279L7'
Will write to volume '000279L7' in slot 3.
What going on? If it can help, here’s the output of ‘lsscsi -g’ (I removed the
non-tape + changer lines):
[1:0:4:0] tape IBM ULTRIUM-HH7 G9Q1 /dev/st0 /dev/sg10
[2:0:4:0] tape IBM ULTRIUM-HH7 G9Q1 /dev/st1 /dev/sg13
[2:0:4:1] mediumx SPECTRA PYTHON 2000 /dev/sch0 /dev/sg14
And here’s an output of the first few lines of the command ‘mtx status’:
Data Transfer Element 0
Storage Changer /dev/changer:2 Drives, 48 Slots ( 1 Import/Export )
Data Transfer Element 0:Empty
Data Transfer Element 1:Full (Storage Element 3 Loaded):VolumeTag = 000279L7
Storage Element 1:Full :VolumeTag=000277L7
Storage Element 2:Full :VolumeTag=000278L7
Storage Element 3:Empty
Storage Element 4:Full :VolumeTag=000280L7
I’m using a 50 slot SpectraLogic T50e library with two LTO7 IBM drives.
Thanks!
This message is the property of CARBONITE, INC. and may contain confidential or
privileged information.
If this message has been delivered to you by mistake, then do not copy or
deliver this message to anyone. Instead, destroy it and notify me by reply
e-mail