Has anyone done quantitative testing to pick the best fitness function? Car/mdd seems to work well, better than k-ratio or sharpe in my personal testing.
Haven't tried Ulcer performance index. I just woundered what others have found. Since the fitness function has such a major impact on the system that results, it seems that a good fitness function should help the system perform well in walk forward testing. This could be measured by walk forward testing the same system with different fitness functions and comparing how they do in the out of sample data. I have been experimenting with a new fitness function I call "pessimistic car/mdd". It uses a dll to resample the trade list after each run 10,000 times, similar to a bootstrap method. It finds the histogram of the resampled car and mdd values, then calculates car/mdd based on average car - 1 stdev and mdd + 1 stdev. The goal of this fitness function is to minimize the impact of data mining.