Hello,

I mainly use index and futures contracts.

Future's trading hours range is wider than index.

Fut hours : 0800 - 2200
Ind hours : 0900 - 1730

My intraday settings are :

Show day session only
Start RTH 0800 End RTH 2159
Start ETH 2200 End ETH 0759

Daily time compression Day/Night session as  defined above

Time shift 0
unchecck mixed EOD.intraday data
check request data RT sources

Base time interval : 1 minute

It works fine for future.


My question: 

The issue is the use of fibonaci extension tool in a weekly chart on Index ( 
the hours shortest range).
Into the properties :
the Start X time is 1959    
the End  X time is 1959
the Third  X time is 1854

This is because of extra quotation send after market hour's. Of course a 
database manual correction is overwrited by 
backfilling and quite useless.


How can I keep Hour's RTH and Hour's ETH for future and force another time 
concerning index ? I mean to display 0900 - 1730 on Index and ignore extra 
quotation.

The consequences are I cannot manually write the Fibo extension values into the 
properties. The display is wrong whatever 
the position of magnet is ON or OFF.
The same issue with Fibo retracement.



Thank you for your help

Best regards

Reply via email to