Yes, that's true.

NB: usually no need to code it explicitely, as during backtesting redundant
signals are automatically removed (except if you use SIGSCALEUP,
SIGSCALEDOWN signals), because AB allows only 1 position of a stock in a
portfolio at any given time.

Just look in the doc for custom back tester info, and/or inspect the
detailed log generated by the back tester.

2009/12/1 rink <[email protected]>

>
>
> ok
> is it like if i buy 200 day high and 100 day low
> suppose if i get signal on 10 oct to buy
> next day there is another 200 day high so the system won't buy it again
> unless next sell signal come
> reply me if  i am right?
> thankyou for your great help
>
>
> Robert Chevallier wrote:
>
>
> Suppose you have the following Buy/Sell arrays
>
>  Buy: 0 1 1 0 1 0 0 0 0 0 1 1
> Sell: 0 0 0 1 0 0 1 1 1 1 0 0
>
>  ExRem (Buy, Sell ) = 0 1 0 0 1 0 0 0 0 0 1 0
> ExRem (Sell, Buy)  = 0 0 0 1 0 0 1 0 0 0 0 0
>
>  It will remove redundants signals (ie: if you have multiple Buy signals,
> only the 1st one will be keep (until the next Sell signal is raised))
>
> 2009/12/1 rink <[email protected]>
>
>>
>>
>> Hello everybody
>> please elaborate in simple english what is this formula?
>> i read help file but cant understand it
>> says removes excessive signals:
>> returns 1 on the first occurence of "true" signal in Array1
>> then returns 0 until Array2 is true even if there are "true" signals in
>> Array1
>>
>> in this formula i see this
>> Buy = H > Ref(HHV(H,200),-1);
>> BuyPrice = Ref(HHV(H,200),-1);
>> Sell = L < Ref(LLV(L,100),-1);
>> SellPrice = Ref(LLV(L,100),-1);
>>
>> Buy = ExRem(Buy,Sell);
>> Sell = ExRem(Sell,Buy);
>>
>> Short = L < Ref(LLV(L,200),-1);
>> ShortPrice = Ref(LLV(L,200),-1);
>> Cover = H > Ref(HHV(H,100),-1);
>> CoverPrice = Ref(HHV(H,100),-1);
>>
>>
>
>  
>

Reply via email to