The specs are not much different than the 450TL.  I've used the 450TL and
6C21 interchangeably in the same rig.



The tube has an oddball filament voltage something like 8.1 volts. The Eimac spec sheet says that it was designed for radar pulse modulator service. I once read somewhere that it is basically identical to a 450TL (or TH?), but that the filament voltage rating was increased to give more cathode emission, to accomodate peak outupt power in the 10's of kilowatts. This is at the expense of tube life. If the tube is run at 7.5 volts it will do just fine in modulator or rf power amp service, and will last much longer. Essentially, Eimac said run a 450T's filament voltage up, and it will deliver incredible peak power while it lasts, but will have a short life.

k4kyv