Corrections:

I use a pushpull final with separate grid and plate current meters FOR EACH TUBE, so this requires two separate grid leaks, one for each tube, a separate protective bias supply for each tube, and of course, a separate filament transformer for each tube.

I never liked putting the plate current meter between the hv transformer midtap and ground, unless the filter caps are returned directly to the transformer. Otherwise, the charging current of the filter caps shows up on the meter, and with large enough caps, could actually damage the meters on startup. The bleeder needs to go to the PLATE TRANSFORMER MIDTAP as well, or else the meter will read plate current plus bleeder current.

Don k4kyv

_________________________________________________________________