It appears that I have found the problem in my HRO60. I turned it on one day last week and all I could hear was floor noise. I couldn't even hear the xtal calibrator and all drawers(bands) were the same. After much poking and prodding and tube testing, come to find out the 4H4 has a broken filament wire, which means that the HF oscillator and the mixer aren't getting any filament volts. Now I need a replacement 4H4. Anyone have a spare they would be willing to part with? I have a 7H4B but when I plugged it in I get 12VAC out to the mixer and HF osc filaments. My HF Oscillator tube 6C4 is really weak so I need one of them too.

Help would be appreciated.

Bob W6TR Florida

Reply via email to