"Mike Dorworth, K4XM" <[EMAIL PROTECTED]>
On a BC-610 using a external VFO, just kill exicitation, ALL METERS fall to
ZERO, the B plus will go to 4000 VOLTS and if you have bypassed the
interlock and touch the link you will be GONE, Forget the meters! Trust the
stick!  I know!

As I recall the 610 doesn't have a plate voltage meter. Every rig should have one. Even though it can fail, it offers one more stage of redundancy of protection. When I shut off my plate supply and see the plate volt meter slowly drop back to zero, I can be 99+% sure there is no high voltage. On my rig, all the grid and plate current meters drop to zero key-up on CW as well.

That's one reason why all my HV supplies shut down on standby. I don't like the idea of HV silently lurking in the rig when it's not in use. If I ever did slip up, I think I would have a better chance of survival discharging a capacitor through my body, than serving as a load resistor on an active power supply.

Besides, keeping the HV on all the time often generates noise and hash in the receiver.

Don k4kyv

_______________________________________________________________

This message was typed using the DVORAK keyboard layout. Try it - you'll like it.
http://www.mwbrooks.com/dvorak/
http://gigliwood.com/abcd/


Reply via email to