Rick/K5IZ
In a Pi configuration for the BTA-1R2 would a 10kv vacuum variable be
sufficient for the input variable? My calculations indicate a 12kv
would be ideal and a 15kv would be best, however, I have located a 10kv
at a decent price. My intentions are to set it up for 75 meters at
first, but would like to install components capable of going down to 160
if later desired. So, I figure a 100pf - 300pf input variable should
work. For the output I figure a 1100pf - 2400pf would do the trick. If
I can use a vacuum relay to switch a tap on the coil I think it will
work. What do ya'll think?