Mark,
I have found that the best way to check a transformer is to use a HI Pot
tester or an insulation tester like a megger with about 5kv capability. I'm
fortunate to have access to a 5KV jobber at work. Anything less than 500K
ohms would be suspect.
You could go to Rich Measures webpage. I believe he has a neat schematic for
HI pot testing tubes which would accomplish the same thing.
Mod-U-Lator,
Mike(y)
W3SLK
----- Original Message -----
From: "Mark Foltarz" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Wednesday, September 20, 2006 6:53 PM
Subject: [AMRadio] Seeking advice on testing modulation transformers
I am sure the following has happened to all of us.
You build a transmitter or modulator using a transformer that you have had
around for years.
You then apply power only to find a short to case or worse on the
cherished
modulation transformer.
Well, I would like to avoid that with several chunks o' iron I have here.
Specifically, I have the big Thordarson multimatch, a pair of those RCA
5500
: 5500 surplus units, and a mod transformer from a BC610E.
I was thinking of applying power between case and a terminal and looking
for
leakage.
In the past I have even run a mod transformer with a case leakage on a
piece
phenolic with favorable results.
By the way, does anyone have any experience using the RCA 5500 5500
units?
TNX
de KA4JVY
Mark
__________________________________________________
Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around
http://mail.yahoo.com
______________________________________________________________
AMRadio mailing list
List Home: http://mailman.qth.net/mailman/listinfo/amradio
Partner Website: http://www.amfone.net
Help: http://mailman.qth.net/mmfaq.html
Post: mailto:[email protected]
______________________________________________________________
AMRadio mailing list
List Home: http://mailman.qth.net/mailman/listinfo/amradio
Partner Website: http://www.amfone.net
Help: http://mailman.qth.net/mmfaq.html
Post: mailto:[email protected]