I am not having much luck finding a HV xformer for my power supply so an
idea occurred to me that I would like to pass around.
MFJ has a 900v one for about $100. Is there any reason why I can not
use two of these and tie one side of the secondaries together and call
that the center tap and have an 1800v ct transformer/s?
I am using 866's so I must have a center tap.
Second question is:
Mine has the HV going to the choke and then to two 4 mf 3kv caps in
parallel. Is it not more conventional to put a cap on each side of the
choke or two chokes for a choke input filter?
What would I gain or lose by moving one of the caps to the HV side?
Thanks,
js
--
PHOTO OF THE WEEK: http://schmidling.com/pow.htm
Astronomy, Beer, Cheese, Fiber,Gems, Sausage,Silver http://schmidling.com
______________________________________________________________
AMRadio mailing list
List Home: http://mailman.qth.net/mailman/listinfo/amradio
Partner Website: http://www.amfone.net
Help: http://mailman.qth.net/mmfaq.html
Post: mailto:[email protected]