I am not having much luck finding a HV xformer for my power supply so an idea occurred to me that I would like to pass around.

MFJ has a 900v one for about $100. Is there any reason why I can not use two of these and tie one side of the secondaries together and call that the center tap and have an 1800v ct transformer/s?

I am using 866's so I must have a center tap.

Second question is:

Mine has the HV going to the choke and then to two 4 mf 3kv caps in parallel. Is it not more conventional to put a cap on each side of the choke or two chokes for a choke input filter?

What would I gain or lose by moving one of the caps to the HV side?

Thanks,

js


--