Gary Schafer wrote:

Now if you put two transformer secondary's in series and use a BRIDGE
rectifier you don't have the core saturation problem because there is no DC
in the individual cores. Current flows both ways in each transformer over
the full cycle.

Now that we settled that, we have learned something but it does not help much.

To review the problem.....

An 866 power supply requires a center tapped transformer. These are hard to come by these days because all recent equipment is solid state and use bridges which do not require center tapped transformers.

There is little reason to tie two low voltage xformers together because a single high voltage one is probably less expensive and easier to come by.

I suggested doing it to simulate a CT xformer with readily available parts.

Anyway, I got my answer and thank all for it.

js

--