Hi Les,

Like Grant said check those line bypass caps. I have a 500 A, they are still present, and I don't have any trouble. I use a 3 wire cord on mine.

If you don't mind, why are your using a GFI? Around here the code only require them within 3 ft. of a water source. Sometimes RF can give them fits as well. So if you aren't violating code, I would remove the GRI and put in a standard socket. First you might get a long extension cord and try it in a standard socket to see what happens. If it opens a circuit breaker, then find out why.

Have fun and live it up.

73

Jim/W5JO


----- Original Message ----- From: "Les Zwiebel

Am restoring a 500C. The power supply trips the GFI. Filter caps have been replaced. If the filtering circuit and caps have some slight inherent leakage, should I bypass or eliminate them? Use a 3 wire to 2 wire adapter plug at the wall? (I would prefer to keep it a 3-wire line.) Eliminate the GFI on that wall socket? Anyone been down this road before?
   Thanks in advance.
   (((((73)))))
   Les
   ---===WB6ORZ===---

______________________________________________________________
Our Main Website: http://www.amfone.net
AMRadio mailing list
Searchable Archives: http://www.mail-archive.com/[email protected]/
List Rules (must read!): http://w5ami.net/amradiofaq.html
List Home: http://mailman.qth.net/mailman/listinfo/amradio
Help: http://mailman.qth.net/mmfaq.html
Post: mailto:[email protected]
To unsubscribe, send an email to [EMAIL PROTECTED] with
the word unsubscribe in the message body.

Reply via email to