Hello,
Just some hints:
Has analog detected the right logformat? Add "DEBUG ON" to your
cfg-file and check the debug output (something like "Detect that its in
Microsofts version of extended format"
should appear) on the screen.
You may force analog to assume that it is IIS by adding "LOGFORMAT
MS-EXTENDED" to your
cfg file.
You may also specify your own LOGFORMAT, search this mailing list, I think
there were some
suggestions for IIS (or look at the docs).
good luck,
Thomas
----- Original Message -----
From: "Scherner Norbert" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, September 14, 2000 6:25 PM
Subject: [analog-help] Logformat of the MS IIS 5.0
> Hi,
>
> I can't get the rigth LOGFORMAT for MS IIS 5.0.
>
> Who can help me ?
>
> #Fields: date time c-ip cs-username s-sitename s-computername s-ip s-port
cs-method cs-uri-stem cs-uri-query sc-status sc-win32-status sc-bytes
cs-bytes time-taken cs-version cs-host cs(User-Agent) cs(Cookie) cs(Referer)
> 2000-09-14 12:58:02 139.25.99.55 - W3SVC3 M66971PP 139.25.101.114 81 GET
/haensse2/Default.asp - 200 0 0 217 15 HTTP/1.1 139.25.101.114
Mozilla/4.0+(compatible;+MSIE+5.01;+Windows+NT+5.0) - -
>
> Kind regards
>
> Norbert
------------------------------------------------------------------------
This is the analog-help mailing list. To unsubscribe from this
mailing list, send mail to [EMAIL PROTECTED]
with "unsubscribe" in the main BODY OF THE MESSAGE.
List archived at http://www.mail-archive.com/[email protected]/
------------------------------------------------------------------------