Hi all, Carlos from LACNIC here. Some of you may remember from Jakarta.
There were no malfunctions in the TA per-se. From what we have been able to
reconstruct from the information we have (after engaging our own team,
PacketVis and NIC Brasil) what we believe is that some of PacketVis' probes
could not establish a connection with NIC.br's repository.
The math is clear, the amount of prefixes that PacketVis claims 'dissapeared'
matches NIC.br's VRP count exactly. Bear in mind that NIC.br's repository is a
delegated TA from LACNIC's own and we as a region have a unique feature where
NIC.br's repo accounts for 45% of all of the region's VRPs.
This was not a widespread issue. My battery of RPs running in Akamai/Linode and
in Montevideo (LACNIC HQ) did not detect any service disruptions for example.
Thanks for your interest. Looking forward to meeting APNIC's wonderful
community again soon.
/Carlos