Hi,

On ECN and its support this came to my mind during the presentation today: I 
assume that most of the results of characterization would be different with ECN 
present and supported (as you also mention in section 2.4). I am not quite sure 
what would be a "solution" when it comes to the document, still it seems to me 
that characterization of the AQM algorithm when ECN is present and supported 
should be also required. Maybe it is even more important in the long term than 
without ECN.

Cheers,
Szilveszter