On Oct 11, 2017, at 19:31, Luke Kenneth Casson Leighton <[email protected]> wrote:
> 
> https://ez.analog.com/docs/DOC-11303
> 
> Each TMDS signal shall have single ended impedance of 50 Ω ± 10%.
> Each TMDS pair shall have differential impedance of 100 Ω ± 5%.
> 
> whoops.... :)  89 ohm... 50 ohm.  89 ohm... 50 ohm.  oops... :)

Well, if the reported impedance is the single-ended impedance of those lines we 
have considerable margin to burn and should aggressively pursue the taper 
structure and bring in the keepouts at each end.

For the geometry that fit our constraints, we calculated a single-ended 
impedance of ~72 Ohm and differential impedance of ~111 Ohm (which corresponds 
to a tolerance of 11%).
_______________________________________________
arm-netbook mailing list [email protected]
http://lists.phcomp.co.uk/mailman/listinfo/arm-netbook
Send large attachments to [email protected]

Reply via email to