Not sure anyone responded to this...

It's my understanding that the Software License Management engine in 703
only works with the BMC_Product (and subclass) CI entries against the
Product Categories that are attached to the contract.  In addition, I don't
believe that you can attach the particular keys on the contract to
particular Categories.
>From what I've seen with the tool, I don't think you have misunderstood
anything - 

Janie


-----Original Message-----
From: Action Request System discussion list(ARSList)
[mailto:[email protected]] On Behalf Of Frank Caruso
Sent: Wednesday, November 18, 2009 10:49 PM
To: [email protected]
Subject: Asset Management Software License

ITMS 7.03

Still trying to figure out the Software License management module ...

What I have so far is that I've created a Software Contract record for
company A. This contract covers several software products, 10. So I
added each as a Licensable Product. I then added under License Details
the keys that are associated with each product with the total number
of licenses, roughly 50. As I add each key the total license count is
accumulating on the contract record. However, there is no way to
associate the key to a product.

The next thing I was hoping to do was start relating CI's (Computer
Systems) to the software contract. I figured this would make the most
sense as the keys are tied to those CIs. However, this does not appear
to be the way the tool works. I have to relate a System Software CI to
the Software Contract. This will then decrement the total number of
licenses for the contract, not at the key level. I then thought if I
relate Computer Systems to the System Software CI that it would also
decrement the license count on the contract record. No such luck. The
only way to decrement the license count is to relate CIs that match at
all 5 levels: Tier 1,2,3, Product Name and Mfct. And still this is
being done at the contract level not at the key level so I would have
to manually go to each key and update the counts, which amazingly
enough updates the counts at the contract level.

Can anybody speak to these issues and let me know whether I understand
correctly how the module works?

Thank you.

Frank Caruso
Iraq

____________________________________________________________________________
___
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
Platinum Sponsor:[email protected] ARSlist: "Where the Answers Are"

_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
Platinum Sponsor:[email protected] ARSlist: "Where the Answers Are"

Reply via email to